Getting your cold storage temperatures right is one of the most fundamental parts of food safety compliance in the UK. It is also one of the first things an Environmental Health Officer will check. Yet many food businesses still have fridges running warmer than they should, with no records to show what temperatures were on any given day.
This guide covers the legal temperature requirements, what to record and how often, what to do when something goes wrong, and how to demonstrate to an EHO that your cold chain is under control.
What the Law Actually Says
The relevant UK legislation is the Food Safety and Hygiene (England) Regulations 2013 (with equivalent regulations in Scotland, Wales and Northern Ireland). The key provisions are:
- Food which is likely to support the growth of pathogenic micro-organisms or the formation of toxins must not be kept at temperatures that would result in a risk to health
- For most chilled foods, this means keeping them at 8°C or below
- Frozen foods must be stored at -18°C or below
- Hot food must be held at 63°C or above
There is a two-hour rule that applies to chilled foods temporarily outside refrigeration: food can be kept above 8°C for a single period of up to two hours (for example during preparation or service). If this window is exceeded, the food must either be used immediately or discarded.
Note on 5°C vs 8°C: Many food safety advisers and EHOs recommend targeting 5°C rather than the legal maximum of 8°C. This is because a fridge running at 7.5°C gives almost no margin for temperature fluctuations caused by door openings, large loads of warm food or ambient kitchen heat. Operating at 0 to 5°C gives you a meaningful safety buffer.
Foods That Must Be Kept Under Temperature Control
Not all food legally requires refrigeration, but the following categories do:
- Raw meat, poultry, fish and seafood
- Cooked meat and cooked fish products
- Dairy products including milk, cream, soft cheeses and custard
- Smoked or cured fish and meat (unless shelf-stable)
- Prepared ready-to-eat foods including sandwiches, salads and sushi
- Foods containing raw eggs (mayonnaise, mousses, desserts)
- Cut fruits and vegetables (as they present a cross-contamination risk)
- Any food with a "use by" date that specifies refrigeration
How Often to Check and Record Temperatures
UK food safety guidance recommends checking all refrigeration and freezer units at least twice per trading day, typically at the start and end of service. In busy kitchens, checking at the start, middle and end of service gives a more complete picture and helps catch problems before large quantities of food are at risk.
Each check should record:
- The date and time
- Which unit was checked
- The temperature reading
- The name of the person who took the reading
- Any corrective action taken if the temperature was out of range
Probe vs display thermometer: Built-in display thermometers on refrigeration units can drift over time and are not always accurate. For compliance purposes, checking with a calibrated probe thermometer inserted into a food product or a glass of water placed in the fridge gives a more reliable reading. A combination of display temperature and probe checks gives the best evidence.
Temperature Logging: What EHOs Look For
When an EHO reviews your temperature records, they are looking for evidence of a consistent, working system. Specifically:
| What They Check | Pass | Concern |
|---|---|---|
| Frequency of checks | Twice daily minimum, every trading day | Missing days, infrequent checks, gaps at weekends |
| Readings within range | Consistently at or below 5°C (8°C legal max) | Readings above 5°C but below 8°C require explanation |
| Out-of-range entries | Corrective action noted alongside the out-of-range reading | No action noted, or same issue recurring without resolution |
| Signed records | Every entry has a name or initials | Unsigned entries suggest records may be fabricated after the fact |
| All units covered | Every fridge and freezer on the premises is logged | Some units missing from the log entirely |
What to Do When a Fridge Goes Out of Range
A single high reading is not automatically a crisis. What matters is how you respond, and that your response is recorded.
Immediate steps
- Note the out-of-range temperature in your log, along with the time and your name
- Check whether the fridge door has been left open or a large volume of warm food was recently loaded
- Take a second reading 30 minutes later to check whether the temperature is recovering
- If the fridge is above 8°C and not recovering, move all chilled foods to another unit or to an insulated container with ice
- Assess the food: if it has been above 8°C for longer than two hours, it must be discarded
- Record the corrective action taken and when
Longer-term response
If the same fridge repeatedly reads high, it needs to be serviced or replaced. A recurring out-of-range temperature with no corresponding service record is exactly the kind of pattern an EHO will flag as evidence that your food safety management system is not working effectively.
Never discard the food silently. If food has to be thrown away due to a temperature failure, record it: what was discarded, how much, why and when. This demonstrates your system is working, not that it failed.
Probe Calibration
A probe thermometer that reads 3°C when the food is actually at 7°C is worse than no probe at all. Calibration matters. The standard method for food businesses is the ice slurry test:
- Fill a container with crushed ice and add just enough cold water to create a slurry
- Insert the probe and wait 30 seconds
- The reading should be between -1°C and +1°C
- Record the reading, the date and your name
Calibrate probes at the start of each week, or more frequently during busy periods. If a probe reads outside -1 to +1°C in ice slurry, it must be taken out of use and replaced or professionally calibrated.
Freezer Temperatures and Defrost Cycles
Commercial freezers should run at -18°C or below. Readings of -15°C to -17°C are a warning sign that the unit is struggling or in need of defrosting. Food safety is not immediately compromised at these temperatures, but the unit should be serviced before it warms further.
During a planned defrost cycle, frozen foods should be transferred to another freezer. If this is not possible, record the start and end times of the defrost and the temperatures throughout. Foods that partially thaw during a defrost and are then refrozen are not automatically unsafe, but this must be risk-assessed and documented.
Common Mistakes That Lead to Poor EHO Scores
- Logging only when temperatures are good. If your records show three months of perfect readings with no variation at all, an EHO may question whether they are genuine. Real fridge temperatures fluctuate slightly.
- Recording the fridge display, not the food temperature. Display thermometers can be inaccurate. Use a calibrated probe for at least some checks.
- Not recording corrective actions. An out-of-range reading with no follow-up note suggests your system is not functioning as it should.
- Forgetting weekend checks. If your business is open seven days a week, your records must cover all seven days. A business that is closed on Sundays should note this in the log.
- Using one log for multiple units. Each fridge and freezer should have its own clearly identified record so any problem can be attributed to a specific piece of equipment.